Sistemas
Barreras de seguridad
System overview
Standard Constructions/Designs
EasyRail
SafetyRail
SuperRail
MaxiRail
BridgeGuard
BeSt-Connect
VecuStop
SPECIAL
Sistemas moviles
Senalization horizontal de carreteras
Amphibienguard
Solar Systems
InduLeit
màs servicios

Servicios
referencias

La Compania
Novedades
Cronica de VR
Sucursales
Contactos
Personas a Contactar
Como encontrarnos
Página de inicio
Aspectos legales
Busca

System overview

Overview of the EN 1317 tested guardrail systems RAL-RG 620:

To see the drawing of our products, please select the drawing-number and to see more information about the system, please select the drawing-desecription. 

containment level N2, piled in systems

system

drawing

drawing-number

containment level

working width

impact severity level

test length

ESP/4.0

 

S1.1-110

N2

W5

WN = 1,6 m

A

60 m

ESP/2.0

S1.1-111

N2

W4

WN = 1,3 m

A

60 m

ESP Plus/2.0

 

S1.1-112

S1.1-113

N2

W4

WN = 1,2 m

A

60 m

ESP Plus W1

S8.1-101

N2

W1

B

40 m

ESP Fortis/0.66

 

N2

W2

WN = 0,7 m

B

 

ESP Fortis/2.0

 

N2

W4

WN = 1,2 m

A

 

ESP BOS

S7.1-101

N2

W3

B

20 m

EASY-RAIL 6.0

ko1509
ko1510

N2

W5

A

84 m

EASY-RAIL 2.0

ko1501
ko1502

N2

W3

A

52 m

EASY-RAIL 1.33

ko1505
ko1506

N2

W2

A

48 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

containment level H1, piled in systems

system

drawing

drawing-number

containment level

working width

impact severity level

test length

EDSP/2.0

 

S1.1-120

H1

W5

WN = 1,6 m

A

60 m

EDSP/1.33

S1.1-121

H1

W4

WN = 1,2 m

A

60 m

DDSP/4.00

 

S1.1-130

H1

W6

WN = 1,9 m

A

60 m

PSSK/2.0

 

S1.1-210

H1

W4

WN = 1,2 m

A

64 m

PSUK/2.0

 

S1.1-220

H1

W4

WN = 1,1 m

A

64 m

EASY-RAIL 1.33

ko1505
ko1506

H1

W3

A

60 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

containment level H2, piled in systems

system

drawing

drawing-number

containment level

working width

impact severity level

test length

DDSP/1.33 SL

 

S1.1-131

H2

W7

WN = 2,3 m

A

64 m

EDSP/2.0

dual

 

(acting effectively with double barrier section only)

with gradient = 1:10

 

S1.1-122

H2

W8

WN = 2,7 m

A

68 m

SUPER-RAIL light


S1.1-314

H2

W5

WN = 1,5 m

 B 

 52 m

SUPER-RAIL light dual


 S1.1-322

H2

 
W5
WN = 1,5 m

B

 52 m

SUPER-RAIL light dual with gradient


 

H2

W5

WN = 1,5 m

B

52 m

SUPER-RAIL ECO

S2.3-101

H2

W4

B

52 m

SUPER-RAIL ECO double sided

S3.1-101

H2

W4

B

52 m

SUPER-RAIL

 

S1.1-310

H2

W4

WN = 1,3 m

A

40 m

SUPER-RAIL

dual

 

(acting effectively with single barrier section already)

 

 

S1.1-320

H2

W4

WN = 1,3 m

A

40 m

SUPER-RAIL

dual

with gradient

 

(acting effectively with single barrier section already)

 

 

S1.1-321

H2

W4

WN = 1,3 m

A

40 m

SUPER-RAIL

double sided

 

S1.1-330

H2

W4

WN = 1,2 m

B

60 m

SUPER-RAIL

double sided

with gradient

 

S1.1-331

H2

W4

WN = 1,2 m

B

60 m

SUPER-RAIL

VZB

 

S1.1-313

H2

W3

WN = 0,9 m

including static part impact basement

B

28 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

containment level H4b, piled in systems

System

drawing

drawing-number

containment level

working width

impact severity level

test length

SUPER-RAIL

 

S1.1-310

H4b

W7

WN = 2,2 m

A

76 m

SUPER-RAIL

dual

 

(acting effectively with single barrier section already)

 with gradient  = 1:10

 

S1.1-320

H4b

W7

WN = 2,2 m

A

76 m

SUPER-RAIL

Plus

 

S1.1-340

H4b*

W5*

B

76 m

MAXI-RAIL

 

S1.1-410

H4b

W6

WN = 2,1 m

B

92 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

containment level H1, systems on structures

System

drawing

drawing-number

containment level

working width

impact severity level

test length

EDSP-

on sructures/1.33 (add. Parapet)

 

 

S1.2-120

H1

W5

WN = 1,6 m

A

80 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

containment level H2, systems on structures

system

drawing

drawing-number

containment level

working width

impact severity level

test length

EDSP-

on structures/1.33 (add. Parapet)

 

 

S1.2-120

H2

W7

WN = 2,2 m

A

80 m

SUPER-RAIL

light on structures

S1.2-350

H2

W4

B

36 m

SUPER-RAIL

on structures

 

S1.2-310

H2

W4

WN = 1,2 m

B

36 m

SUPER-RAIL

Dual on structures

 

(acting effectively with single barrier section already)

 

 

S1.2-320

H2

W4

WN = 1,2 m

B

36 m

SAFETY-RAIL

 

S1.2-510

H2

W4

WN = 1,1 m

B

32 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

containment level H4b, systems on structures

system

drawing

drawing-number

containment level

working width

impact severity level

test length

SUPER-RAIL

dual on structures

 

(acting effectively with single barrier section already)

 

 

S1.2-320

H4b*

W7*

B

40 m

SUPER-RAIL

Plus on structures

(add. Parapet)

 

 

S1.2-340

H4b

W6

WN = 2,1 m

B

80 m

BRIDGE-GUARD

 

BG_ko01

H4b

W5

WN = 1,4 m

B

80 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

containment level H2, transition from steel to concrete

system

drawing

drawing-number

containment level

working width

impact severity level

test length

BeStCONNECT EDSP

 

BeStCONNECT

H2

W2

WN = 0,8 m

C

27,10 m

BeStCONNECT SR

 

BeStCONNECT SR

H2

W2

WN = 0,7 m

C

23,10 m

 

To see the drawing of our products, please select the drawing number and to see more information about the system, please select the drawing-descripbtionW = working width class, WN = normalised working width according to EN 1317-2